aylook talks to your alarm and fire panel - not just to a hard drive.
Most video systems record. aylook exchanges events with the panel: it knows when the system is armed, which zone triggered, and sends video verification back - instead of leaving the installer to bridge two separate systems by hand.
Panel connects
aylook links to the alarm or fire panel via its native protocol - no generic GET/POST bridge that can silently fail.
Zones map to cameras
Each panel zone is associated with the camera(s) covering it, so an alarm event has a matching video source.
Event + video arrive together
When a zone triggers, the installer or end user sees the event and the verifying clip in the same app - not two systems to check.
Supported alarm and fire panels
aylook can be fitted with a software application that integrates the most important and widely used alarm panels equipped with a LAN card. Full integration between cameras, sensors and protected areas lets you supervise the system with a few clicks.
Details are from the aylook panel integration manual, version 1.8 (06/07/2025).
| Brand and models | Sensors | Areas / programs | Outputs | Clear alarm memory | Name import | What the panel needs | Notes |
|---|---|---|---|---|---|---|---|
| AVSAVS Ultra, AVS Xtream 6, 6 B, 32, 32 B, 64, 64 B, 640 | Alarm, alarm memory, tamper | Armed, disarmed, alarm memory | Yes (only if set as user outputs) | No | No | EWEB PLUS or XWEB module | Multi PIN: no (uses the PIN set in setup). Up to 4 simultaneous connections, each with a different PIN. Sector alarm memory supported from aylook 9.1.11; in earlier versions create actions with the zones. |
| EL.MOProxima, ViDomo, Pregio, Titania, ETR | Alarm, alarm memory. Zone tamper not supported; sensors on RPX485 serial repeaters not supported | Sectors: armed, disarmed | Yes (must be set as manual control) | No | Yes (started manually, slow sync) | Nothing to install | Multi PIN: no. Sector alarm memory is not supported, so the panel never goes into alarm; create actions with the zones. The user needs "Piccola Manutenzione" enabled. |
| InimPrime | Alarm, alarm memory, tamper; double zones and virtual terminals | Armed, disarmed, alarm memory. Scenarios: not supported | Yes | Yes | Yes | INIM Prime LAN board, API key enabled | Multi PIN: no. Only standard terminals. Virtual zones can be driven by virtual outputs through aylook actions, so the panel or area can be put into alarm when the video analysis triggers. |
| InimSmartLiving 10-15, 10-50, 10-100 | Alarm, alarm memory, tamper; double zones | Armed, disarmed, alarm memory, partial arming. Scenarios: not supported | Yes | Yes | Not supported | INIM LAN SI board | Multi PIN: yes, all user PINs. Only standard terminals; seismic zones, keypad terminals, virtual terminals and input-output terminals are not supported. |
| KseniaLares 16-IP, 48-IP, 128-IP, Lares 4.0 | Alarm, alarm memory, tamper, and virtual zones | Armed, disarmed, alarm memory | Yes, including virtual outputs (software timers) | Yes (complete only from the panel) | Yes | Nothing to install | Multi PIN: yes. Maximum zones 16, 40, 96, 140 or 644 and outputs 16, 18, 40, 140 or 644, depending on the model (physical plus virtual). |
| RiscoProSys+, LightSys, LightSys+ | Alarm, alarm memory, tamper | Armed, disarmed, alarm memory | Yes (configured as user code) | No | No | IP Dual Socket network card (so the cloud can still be used) | Multi PIN: no. Zones cannot be excluded while the panel is armed. |
| RiscoProSys 16/40/128 | Alarm, alarm memory, tamper | Armed, disarmed, alarm memory | Yes | No | No | IP Dual Socket network card | Multi PIN: no. |
| SatelIntegra 64, 64 Plus, 128, 128 Plus, 128 WRL, 256 Plus | Alarm, alarm memory, tamper | Armed, disarmed, alarm memory; arming types 1, 2 and 3 supported | Yes (monostable and bistable) | Yes | Yes (from aylook 9.1.11 via XML file exported from DLOADX) | ETHM-1 module; encrypted integration must be disabled | Multi PIN: works with all panel PINs. A wrong PIN is not reported. |
| TecnoalarmTP8-88, TP8-88 PLUS, TP20-440, EV10-50, EV12-150 | Alarm, alarm memory, tamper, exclusion; virtual zones on EV10-50 / EV12-150 (with Zone IP licence) | Programs: arm / disarm; reset alarm memory (from aylook 8.1.11 with ASC and App 2.1.2); arm with zone exclusion (from 8.1.12 with ASC and App 2.1.2) | Remote-control type: 16 on TP8-88, 32 on TP20-440, 36 on EV10-50, 72 on EV12-150 | See programs | Yes (TP8-88P / TP20-440 with at least FW 1.9.00 and Tecno Out 3.5.00; EV10-50 / EV12-150) | Tecno-Out licence; ESP-LAN network module on TP8-88 and TP20-440 | Multi PIN: supported. EV10-50 is integrated only in aylook 9; EV12-150 from aylook 9.1.14. Tecno Out and Tecnoalarm Supervisor cannot be used at the same time. Virtual zones: a camera event can raise an alarm or tamper on a virtual zone, for example when a person is detected while a partition is armed. |
| Tecnofire (fire panels)TFA1, TFA2, TFA4, TSA1, TSM1 | Alarm, alarm memory, tamper | Zones: status view (armed, disarmed, alarm) | Modules: outputs view | Not supported | Yes | Tecno-Out licence; TFNET network module | Multi PIN: supported. Zones cannot be excluded; zone 0 not managed; Tecno Out and Tecnofire Supervisor cannot be used at the same time. |
| UTC (Interlogix)UTC Master | Alarm, alarm memory, tamper | Armed, disarmed, alarm memory | Yes | No | No | Network card | Multi PIN: no. Only the Security configuration with all values at 0 is supported. |
Fire panel integration
aylook also integrates with fire detection panels: cameras activate and notify staff automatically when smoke or flame is detected. Supported models: Tecnofire TFA1, TFA2, TFA4, TSA1, TSM1.
Don't see your panel?